• DC AC 220V 3 HP 10A MPPT VFD Solar Pump Inverter For Submersible Surfact Pump
DC AC 220V 3 HP 10A MPPT VFD Solar Pump Inverter For Submersible Surfact Pump

DC AC 220V 3 HP 10A MPPT VFD Solar Pump Inverter For Submersible Surfact Pump

Product Details:

Place of Origin: China
Brand Name: ZK ZUN
Certification: CE IEC ISO
Model Number: SU100-D2-2R2G-B

Payment & Shipping Terms:

Minimum Order Quantity: 1 Piece
Price: USD 85-120 per piece
Packaging Details: Carton box with flim
Delivery Time: 5-9days
Payment Terms: T/T, L/C, Western Union,, D/P
Supply Ability: 2000pcs per week
Get Best Price Contact Now

Detail Information

Inverter Type: Solar DC/AC Inverter MPPT Efficiency: Built In
Input Voltage Range: 150-440VDC Or 0-220VAC Output Voltage: 3phase 0-220VAC
Inverter Power: 2.2KW 10A Moter Type: Submersible Or Surfact Pump
Output Frequency: 0-50/60HZ Application: Solar Water Pumping
High Light:

3 HP MPPT VFD Solar Pump Inverter

,

10A MPPT VFD Solar Pump Inverter

,

3 Hp Inverter

Product Description

220V 3HP 10A AC DC Single 3 Phase MPPT Solar Pump VFD Inverter
 
ZK SU100 series solar water pump VFD inverter mainly features:

  • Drives well all kind of AC pumps in solar pumping system.
  • MPPT efficiency more than 99%.
  • Multiple control modes, local control, auto start/stop, GPRS remote control.
  • Dry run (under load ) protection, Water tank fulling detect, Maximum current of pump protection
  • Low stop frequency protection, sleep/ wake up function when lack/enough of sunlight radiation.
  • Dual mode input, compatible with DC and AC power input, low and wide range voltage input.
  • The PQ (Power/Flow) performance curve enables calculating the flow output from the pump
  • Multiple pumps protection function, short circuit, phase missing, over current, over voltage...
  • Ambient temperature for using: -10 to +55˚C.

 
How to select the solar panels? need enough DC voltage and Input power at same time.
 

Input voltage, power solar selection
Pumps modelInverte modelsVmpVocTotal Power of solar arrays
110VAC pumpT1 (for 110V)130VDC156VDC

≧ (1.3 to 2.0) rated power of Pump
It is also depend on the quality of solar panels. The higher the power input, performance will be better

220VAC pumpT2 (for 220V)310VDC372VDC
380VAC pumpT3 (for 380V)540VDC648VDC

 
Although solar pump inverter built in high efficiency MPPT tracking arithmetic, up to 99% MPPT efficiency, but also

need to consider many factors of solar radiation. It is no certain rules to determine exactly how many piece solar
panels exactly input for system. If the output frequency can’t get to 50Hz/60Hz, please consider to connect more
solar panels.


Technical specifications:
 

ItemSpecification
Power inputVoltage, frequency

T1: 90V DC to 400V DC or 110V±15% AC, 50/60Hz
T2:150V DC to 450V DC or 220V±15% AC, 50/60Hz
T3: 250V DC to 750V DC or 380V±15% AC, 50/60Hz

 Allowable fluctuationsvoltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2 required
 Power factor≥0.94(with DC reactor)
 Efficiency≥96%
OutputOutput voltageOutput under rated condition: 3 phase, 0~input voltage, inaccuracy<5%
 Output frequency range0-50/60HZ. (0-600HZ for PMSM)
 Output frequency accuracyMax frequency ±0.5%
 Overload capacityG type: 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s
Main control performanceMotor control modeV/F without PG , VC without PG , VC with PG
 Speed control rangeVector control without PG, rated load 1:100;Vector control with PG, rated load 1:1000;
 Steady speed accuracy

VC without PG: ≤2% rated synchronized speed;
VC with PG: ≤0.05% rated synchronized speed

 Starting torque

VC without PG: when 0.5Hz, 150% rated torque;
VC with PG: when 0Hz, 200% rated torque

 Torque response

VC without PG: ≤20ms;
VC with PG: ≤10ms.

 Frequency accuracy

Digit setting: max frequency×±0.01%;
Analog setting: max frequency×±0.2%

 Frequency resolution

Digital setting: 0.01Hz;
Analog setting: maximum frequency × 0.05%

Product
basic functions

DC braking capacity

Starting frequency:0.00~50.00Hz; Braking time:0.0~60.0s;
Braking current:0.0~150.0% rated current

 Torque boost capacity

Auto torque upgrade 0.0%~100.0%;
Manual torque upgrade 0.0%~30.0%

 V/F curve4 modes: one linearity torque characteristic curve ,one self-setting V/F curve mode, one drop torque characteristic curve (1.1- 2.0 powers),and square V/F curve mode.
 Acceleration/Deceleration curve

2 modes: linear Acceleration/Deceleration and S curve Acceleration/Deceleration.
4 sets of ACC/DEC, time unit 0.01s selectable, longest time: 650.00s.

 Rated output voltageRely on power supply voltage compensate function, while motor rated voltage is 100%, set it at the range of 50-100%(output can not over input voltage).
 Voltage auto-adjustmentWhile power supply voltage fluctuates, it can auto-keep constant output voltage.
 Auto energy-saving runningWhile under V/F control mode, according to load situation, auto-optimize output voltage to save energy.
 Standard functionsPID control, speed track, power off restart, jump frequency, upper/lower frequency limit control, program operation, multi- speed, RS485, analog output, frequency impulse output.
 Frequency setting channelsKeyboard digital setting, keyboard potentiometer ,Analog voltage/current terminal AI1,AI2, Communication given and multi-channel terminal selection, Main and auxiliary channel combination, expansion card, supporting different modes switch.
 Feedback input channel

Voltage/Current Terminal AI1, Voltage/Current Terminal AI12, Communication
given, pulse input X5.

 Running command channelOperation panel given,external terminal given, communication given, expansion card given.
 Input command signalStart, stop, FWD/REV, JOG, multi-step speed, reset, ACC/DEC time selection, frequency given channel selection, exterior fault alarm.
Protective functionOvervoltage, under-voltage, current limit, over-current, overload, electric thermal relay, overheat, overvoltage stall, data protection, rapid speed protection, input/output phase failure protection.
EnvironmentInstall placealtitude ≤ 1000m,above 1000m down the rated amount, each increase of 100m down the rated mount of 1%;no condensation, ice ,rain, snow, hail; solar radiation below 700W/㎡, air pressure 70-106 kPa.
 Temperature, humidity-10 ~ + 50 ℃, derating above 40 ℃, maximum temperature 60 ℃ (no-load operation)5% to 95% RH (non-condensing)
 VibrationWhen 9~200Hz, 5.9m/s2(0.6g)
 Storage temperature-30 ~+50℃
 Protection gradeIP20, (IP54 is avaliable)
 Cooling methodForced air cooling
 
 

 
ZK hot selling SU100 series solar pump inverte MPPT efficiency more than 99%. Solar DC and Grid AC input.
 
 
DC AC 220V 3 HP 10A MPPT VFD Solar Pump Inverter For Submersible Surfact Pump 0
 
FAQ:
 
Q1 : What is the solar water pumping Inverter?
ZK Solar pump inverter drives well all kind of water pump including single phase pump and PMSM in solar pumping system, solar DC and Grid AC input. MPPT efficiency more than 99%.
 
Q2: What should be noticed when installing inverter?
Install the Inverter in a place where is well ventilate,cool, dry and water-proof. long services life.
Q3: Do we need to set the parameter before using ?

Our inverter is AI intelligent working, can automatic tracking the DC bus voltage.
You can set parameters if you want other functions like Dry run, full tank detect.
 
Q4:Where is your factory located?
Our factory is located in Shenzhen, China, most welcome to visit us. We can pick up you from the Shenzhen Airport or High Speed Rail Station to our factory.
 
Q5:What is the supply capacity of your factory?
9000pcs inverters can be produced every month.
Export 7000-9000pcs inverters every month, to Thailand, India, Pakistan, the Middle East like Syria, Saudi, Yemen, Turkey, Egypt... All African and South America like Mexico, Brazil.
Sample be delivery around 3-5days, bulk order around 10-30 days.
Support OEM & ODM!

Want to Know more details about this product
I am interested in DC AC 220V 3 HP 10A MPPT VFD Solar Pump Inverter For Submersible Surfact Pump could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.